• Flat & Bend Glass Tempering Furnace Sh-Fab2450-25 New Generation Hot Sale
  • Flat & Bend Glass Tempering Furnace Sh-Fab2450-25 New Generation Hot Sale
  • Flat & Bend Glass Tempering Furnace Sh-Fab2450-25 New Generation Hot Sale

Flat & Bend Glass Tempering Furnace Sh-Fab2450-25 New Generation Hot Sale

Warranty: One Year
Type: Glass Tempering Furnace
Certification: CE
Structure: Horizontal
Control System: PLC
Condition: New
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
SH-FAB2450-25
After-sales Service
Field Installation,on-Line Surport,
Transport Package
Seaworthy Packing Suitable for Long Disatance
Trademark
Easttec
Origin
China
HS Code
8475291900
Production Capacity
5 Sets/Month

Product Description

1.Brief introduction.
1.1. The equipment is the bi-direction reversible struction. It mainly includes loading/unloading section, bending tempering section, heating section(furnace), flat tempering section, unloading/loading section, blower system, electric control cabinet.
The blower system consists of the big blower, the invertor control cabinet, the blower control pneumatic valve, the air duct, the air box, etc. The big blower is adjusted by invertor to be energy-saving.
2.1 Technical Specifications

2.1.1 Equipment Dimension: 34000mm(L) ×4500mm(W)(Excluding air path and big blower room) ×4000mm(H) 
2.1.2 Glass size:
Flat tempering Glass size:
Max flat glass size : 2,440 mm x 5,000 mm     5-19mm
Max flat glass size : 2,440 mm x 1,800 mm     4mm
Min glass size : 100 x 350 mm

Bend tempering Glass size:
Max glass size:  2,440mm×2500mm(Arc length)
Min glass size:  300mm×500mm(Arc length)
Bend tempering glass thickness range: 5mm~19mm
R800mm(5~6mm)
R1000mm(8~10mm) 
R1500mm(12~19mm)
The energy sources consume of production: ≤4.5kwh/m2(according to 5mm  model)
2.1.3 Finished product rate: over 5mm not less than 98%.
2.2 Utilities
2.2.1 Installed power:
Heating :900 kW
Drives : 35 kW
Convection blower:4KW x8=32KW
Flat Quenching : 315KW+160KW
Power requirement: Transformer no less than 1200KVA
Note: The power capacity may be different and should be referring to the actual

2.3 Compressed air(an air tank should be supplied with 0.5M3 at least) :
Volume: 1m3 /min
Pressure : >0.7 MPa

2.4 Suitable glass sorts:
Clear float glass
Coated glasses
Low-e glass(e 0.15-0.02)
Patterned glass
Tinted glass
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now